An HSK vertical incubator cabinet needs 5–7 litres of water per minute. The right flow keeps every tray supplied with oxygen-rich water without washing eggs or creating air bubbles; demand rises as embryos develop, so flow is usually set at the upper end of the range near hatching.
Why flow matters
Developing eggs take oxygen from the water and release ammonia and CO₂. In a vertical incubator the same water passes through every tray, so the bottom tray receives the water that the trays above have already used. Too little flow means the lowest trays run short of oxygen; too much flow can lift eggs and fry and push air into the system.
Practical flow guidelines
- Green eggs to eyed stage: oxygen demand is low. The lower end of the range (about 5 L/min per HSK cabinet) is usually enough.
- Eyed stage to hatch: demand increases sharply. Move towards 7 L/min.
- After hatching: sac fry need even more oxygen. Check the bottom trays first and move fry out before the trays become crowded.
Water quality checklist
| Dissolved oxygen | Keep inflow close to saturation; measure at the outlet of the cabinet, not only the inlet. Many hatcheries aim to keep outlet oxygen above about 7 mg/L. |
|---|---|
| Temperature | Rainbow trout eggs are commonly incubated around 8–12 °C. Avoid sudden changes. |
| Gas saturation | Water from wells or pumps can be supersaturated with gas. Degas it before the incubator to avoid gas bubble disease. |
| Suspended solids | Silt settles on eggs and blocks oxygen exchange. Filter or settle source water. |
| Light | Keep eggs dark; cover cabinets or turn off lights in the incubation room. |
Common mistakes
- Measuring flow only once at the start of the season.
- Checking only the top tray – problems show up first at the bottom.
- Stacking more eggs per tray than the flow can support.
- Letting air enter the inlet line, which creates bubbles under the egg baskets.
These are general guidelines; adjust to your species, strain, water source and local veterinary advice.